Peer review artikel

Optimization of Operating Conditions in Forward Osmosis for Osmotic Membrane Bioreactor

Artikelen

“Objective of this study was to conduct a baseline study of osmotic membrane bioreactor (OMBR) -optimization of operating conditions in forward osmosis (FO). Experiments were conducted with an FO pilot system. Tap water was used as the feed and NaCl and MgSO 4 solutions were used as draw solution. Effects of various operating conditions on flux have been investigated. In addition, pure water permeability of the FO membrane was tested. It was observed that the plant operation could be stablized within 1 h. When the membrane selective layer faced to the feed, a flux of 6.3 lm -2 h -1 (LMH) was achieved at 24 atm osmotic pressure and 25 ÂșC and effects of feed velocity and air velocity on flux were not siganificant under the testing conditions due to low external concentration polarization (ECP). However, when the selective layer faced to the draw solution, the flux was enhanced by 64% due to much reduced internal concentration polarization (ICP), the flux sharply increased with an increase in velocity of the draw solution in the laminar flow pattern range due to a countable effect of dilutive external concentration polarization (DECP) and leveled off after the flow pattern became turbulent. NaCl performed much higher efficiency than MgSO 4 as an osmotic agent due to a greater solute diffusion coefficient of NaCl.”

(Citaat: Qin, J.J., Oo, M.H., et al., – Optimization of Operating Conditions in Forward Osmosis for Osmotic Membrane Bioreactor – The Open Chemical Engineering Journal 3(2009) p.27-32)

Bekijk het artikel
Heeft u een vraag over deze publicatie?